Eaton

Contact our dedicated and knowledgeable team today to find out more information.

APS3-300

  • Rectifier Module(s): EPR48-3G |APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 3
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz
  • DC Output: 21.5v-32v / 43v-57.5v
  • Install Power: 6kW
  • Low Voltage Disconnect: Contactors 200A rated
  • Operating Temperature: -40°C – +70°C
  • Dimensions (H x W x D): 133.4(3U) x 482.6mm(19”) x 306mm(12”)

APS3-400

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 3
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz
  • DC Output: 43v-57.5v
  • Install Power: 6kW
  • Low Voltage Disconnect: Contactors 200A rated
  • Operating Temperature: -40°C – +65°C
  • Dimensions (H x W x D): 133mm(3U) x 482.6mm(19”) x 356mm(14”)

APS6-300

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 6
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz (1 feed per 6 Rectifiers)
  • DC Output: 21.5v-32v / 43v-57.5v
  • Install Power: 8.9kW
  • Low Voltage Disconnect: Contactors 200A rated
  • Operating Temperature: -40°C – +70°C
  • Dimensions (H x W x D): 266mm(6U) x 482.6mm(19”) x 306mm(12”)

APS6-400

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 6
  • Efficiency: 92% or 95%
  • AC Input: 100v – 240v, 50-60Hz (1 feed per 6 Rectifiers)
  • DC Output: 43v-57.5v
  • Install Power: 12kW
  • Low Voltage Disconnect: Priority- 400A | Non-Priority- 200A
  • Operating Temperature: -40°C – +45°C
  • Dimensions (H x W x D): 266mm(6U) x 482.6mm(19”) x 390mm(15.3”)

APS6-500

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 6
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz (1 feed per 6 Rectifiers)
  • DC Output: 21.5v-32v / 43v-57.5v
  • Install Power: 12kW
  • Low Voltage Disconnect: Contactors 400A rated
  • Operating Temperature: -40°C – +70°C
  • Dimensions (H x W x D): 266mm(6U) x 482.6mm(19”) x 306mm(12”)

APS6-600

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 6
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz (1 feed per 6 Rectifiers)
  • DC Output: 43v-57.5v
  • Install Power: 18kW
  • Low Voltage Disconnect: Priority- 400A | Non-Priority- 200A/400A
  • Operating Temperature: -40°C – +70°C
  • Dimensions (H x W x D): 266mm(6U) x 482.6mm(19”) x 306mm(12”)

APS12 Series

  • Rectifier Module(s): EPR48-3G | APR48-3G | APR48-ES
  • Controller: SC200 | SC100
  • Max no. of Modules: 12
  • Efficiency: 92% or 96%
  • AC Input: 100v – 240v, 50-60Hz (1 feed per 6 Rectifiers)
  • DC Output: 43v-57.5v
  • Install Power: 17.2kW
  • Low Voltage Disconnect: Priority- 400A | Non-Priority- 200A
  • Operating Temperature: -40°C – +70°C
  • Dimensions (H x W x D): 399mm(9U) x 482.6mm(19”) x 306mm(12”)